Titanium Grade 5

SYSTEM TI 5-BLANK is a non-precious-dental milling alloy on Titanium-Aluminium-Vanadium Base.
SYSTEM TI5-BLANK is intended for the use of crowns, bridges and prosthesis.

Components-characteristics and use of Titanium Grade 5

Non-precious dental milling alloy on titanium-aluminium-vanadium base
Component of the alloy in %
  • Al: 5,50 – 6,50
  • V: 3,50 – 4,50
  • N: max. 0,05
  • Fe: max. 0,25
  • O: max. 0,13
  • C: max. 0,08
  • H: max. 0,012
  • Ti: Rest
 Characteristics
  • elastic limit: 760 MPa – 850 MPa
  • breaking elongation: 8 % – 14 %
  • Tenacity: 825 MPa – 985 MPa
  • Specific gravity: 4,4 g/cm³
  • melting temperature: 1650°C +/- 50°C
  • WAK (200 – 400°C): ~ 12,4 x10-6K-1
  • Hardness after casting:: 310 HV 10 +/- 41°C
  • Firing temperature: approx. 980 °C
  • System TI 5-Blank consists of a Titanium -Aluminium-Vanadium-alloy.
System TI 5-Blank

System TI 5-Blank is intended for the use of crowns, bridges and framework and only intended for use in the DENTAL FIELD.

Lasering / Welding:

Only with lasering- or plasma device with TIG technology. If required, use a pure Titanium thread grade 1 with Ø = 1,0 –0,25 mm and / or a pure Titanium plate grade 1 with Ø = 0,5 or 0,25 mm.

Ceramic Firing:

Use low-melting ceramics only and follow the manufacturer´s specification.